01
Building envelopes
Facade systems and structural glazing
Curtain walls transfer wind pressure and dead load back to the building while controlling air and water penetration. Unitized panels support rapid high-rise installation; semi-unitized and stick systems suit different grids and site sequences. Structural glazing creates a flush appearance, while spider glazing supports transparent entrances and atriums.
- Check anchors, brackets, mullion deflection and slab-edge tolerance.
- Coordinate movement joints, drainage paths, glass supports and compatible sealants.
- Select the system for module size, access, performance and architectural intent.
Performance mock-ups help verify air, water and structural behaviour before repetitive installation.
02
Residential openings
Aluminium sliding-window systems
Two-, three- and four-track systems are selected by opening width, number of shutters, wind exposure, glass weight and required weather performance.
- Use adequate track, shutter and interlock depth for the design pressure.
- Keep weep holes and drainage chambers clear and directed outside.
- Specify corrosion-resistant rollers, locks and fasteners for coastal locations.
- Check fabrication tolerance, frame squareness, roller capacity and track level.
Large or high-level panels may require reinforced interlocks or additional structural members supported by calculation.
05
Structural performance
Wind load and profile-deflection basics
Wind pressure changes with building height, terrain and exposure. Load moves from the glass through gaskets, beads, shutters, mullions, brackets and anchors into the structure.
- Establish project design pressure from the applicable code and consultant criteria.
- Check glass stress and deflection for actual supported dimensions.
- Verify aluminium profiles in both axes, plus joints, anchors and fasteners.
Indicative pressures and catalogue sizes never replace project-specific engineering and approved shop drawings.
08
Long-term care
Maintenance and facade-safety guidance
Planned inspection protects performance, appearance and public safety. Frequency should reflect height, coastal exposure, pollution, system age and access.
- Inspect sealants, gaskets, glass edges, flashings, fixings and corrosion.
- Clean tracks and drains; adjust rollers, handles and locks.
- Record defects by elevation and prioritize loose panels, cracked glass and leakage.
- Use controlled access, barricading and approved replacement procedures.
Work at height requires an approved method statement, risk assessment, access plan and applicable safety controls.